VOLVO V70 2009 diagnosis with Foxwell GT80 Plus

Here is an auto test with Foxwell GT80 Plus scanner, on VOLVO V70 2009. Foxwellshop engineers has used GT80PLUS to clear all faults .

The procedure is all here.
Before diagnosis, connect GT80 PLUS mux to the car V70.
Then the scanner starts.
Go to Diagnostic->VOLVO->Select vehicle by read VIN->select vehicle transmission




Auto Scan begins here






Some faults there in Park Brake Module (PBM), Central electronic module (CEM), Climate control module (CCM), Driver information module (DIM)
Select Park Brake Module (PBM) to read and clear trouble codes
15
Read codes
16
17
Back to clear codes
18
19
Then do the same to read and clear codes of Central electronic module (CEM), Climate control module (CCM), Driver information module (DIM)
20-23
Done!


2016年9月28日星期三

ECU tuning software: ECM TITANIUM vs WinOLS

Yes, I agree that WinOLS is advised to learn and use ECM TITANIUM not only, why? Because ecm is easier to use for people who start and how easy will be bad habit of using it as a single program.

The problem is that if you only limit yourself to modify the maps that the program shows you the repro is made half and never will draw the maximum power. Besides that such people are all it would do odd jobs because they will not want it easy and strive to learn.

If we want to get the maximum power possible is clear that we must touch the lomitadores by temperature, pressure, and single and I do not care to do it with ECM TITANIUM V1.61 that WinOLS, because if you know where are the maps and what they are for the end result it is the same with any hex editor.

-also have to say that when a car has kilometers and its components, turbo, pump and clutch cylinders are not as when they were new, I would not dream ride up limiters, forward and singles that car for a lot of power to ask the owner because the car breaks something both days and although the owner is aware or is not, the bad reputation you have earned it.

Ecm does not touch those maps unless you want to touch them and that's good for those who are just starting out and have no advice from anyone because they are quite damaging to an engine because they are limiting.

'I've found cases of people who have broken their car to bring an aggressive schedule, yes, I was very well done with WinOLS and such but which merely charged it to load and nothing else because it was a programming he had done well in all those same models peeeero car in this car has not gone well and has broken and clear the fault of the car.

That is not so if the car is touched can not shove that programming for good it is, so one can pull a few hours to make a edc16 much that you did, and do it by touching bdm.

- I wanted to clarify that I if I have to make a repro of a car NOT KNOW OR NOT have done before and do not know the functioning of the ecu, directly buy programming so I make sure that things look good but nevertheless get a lower profit margin.

-also Want to add that when one engages in this semi or professionally and charged for it or not want the thing works against time and more in the automotive world so make no mistake because it is obvious.

-To Finish meant that not everyone seeks to upload it to maximum power, many people want something more cheerful or more drive force but warn you in advance that they do not want to upload to sack power. Above all mature people or carriers.

All saluditos

2016年9月27日星期二

How to solve ElsaWin error 80004005 unspecified error

Tips here are for error 80004005 “unspecified error” in ElsaWin v5.2 electronic service information program.
Error message:
Error 80004005:Unspecified error
Soruce: unknown
Description: not available 

Customer solution:
  1. you must have installedAcrobat readerand svgview
    2.must have installed car data base like in this:
uninstall elsa and reinstall again all :elsa base and data base cd's
uninstall elsa, then reinstall acrobat reader and svgview, then ElsaWin base and then Audi data base cd.
check to have installed audi cd like in my foto :elsa4.0 zip,2 post up.
and must to work
If it didn’t work also, maybe the Elsawin software you installed is corrupted. You can buy tested Elsawin v5.2 or Elsawin v4.0 from obd2france.com. They are tested without issues and work well on Windows xp.

2016年9月26日星期一

(solved) 2016 FVDI2 Renault Abrites error: Unable to autodetect vehicles

It’s aimed to help how to solve error message “unable to autodetect vehicles”in FLYOBD FVDI2 for Renault version 2016.
Model: Renault Talisman or Renault samsung SM6
Error message:
ABRITES Diagnostics for Renault
Unable to autodetect vehicles. Please select it manually.


Analysis from FVDI experts:
It’s normal.
FVDI2 v2016 cannot detect the vehicle automatically.
Users should select the model and year manually.

Then scan for all modules...
(fvdi2 can program the new key / card )
Renault models available:
- Megane II X84 2003-2006
- Renault Megane II Ph2 X84 2007+
- Renault Megane III X95 2009+
- Renault Megane III X95 2011+ **
- Renault Scenic II X64 2003+
- Renault Scenic II Ph2 X64 2007+
- Renault Scenic III X95 2009+
- Renault Scenic III X95 2011+ **
- Renault Laguna II 2000-2005 X56
- Renault Laguna II 2005-2007 Ph2 X74
- Renault Laguna III X91 2007+
- Renault Valsatis X73 2002+
- Renault Valsatis Ph2 X73 2006+
- Renault Espace IV X81 2003-2006
- Renault Espace IV Ph2 X81 2006+
- Renault Master X70 Ph2 2002-2006
- Renault Master X70 Ph3 2007+
- Renault Traffic X83 II 2002-2006
- Renault Traffic II Ph2 X83 2007+
- Renault Kango MUX Ph2 X76 2002-2007
- Renault Kango X61 2008+
- Renault Clio II Ph2 / 3 X65 2002-2006
- Renault Clio Symbol
- Renault Clio Symbol 2010+ (BCM JC) *
- Renault Clio Thalia
- Renault Clio Campus
- Renault Clio Sedan
- Renault Clio Classic
- Renault Clio III 2005+
- Renault Clio III card
- Renault Modus 2004+
- Renault Grand Modus 2008+
- Renault Master III X62 2010+
- Dacia Duster 2010+ (BCM JC) *
- Dacia Logan X90 2004-2008
- Dacia Logan X90 2008+ Ph2
- Dacia Logan 2010+ (BCM JC) *
- Dacia Sandero B90 2008+
- Dacia Sandero 2010+ (BCM JC) *
- Dacia Solenza 2003-2005
- Renault-Samsung SM3 2006+
- Renault-Samsung QM5
- Renault-Samsung SM3
- Renault-Samsung SM5
- Renault Fluence 2009+ *
- Renault Fluence (immobilzier BCM) 2009+
- Renault Fluence (BCM immobilzier) 2011+ **
- Renault Twingo Ph2 X06 2002-2007
- Renault Twingo II X44 2007+
- Opel Vivaro 2002-2006
- Opel Vivaro Ph2 2007+
- Opel Movano 2002-2006 Ph2
- Opel Movano Ph3 2007+
- Opel Movano 2010+
- Nissan Primestar Ph2 2002-2006
- Nissan Primestar Ph3 2007+
- Nissan Platina 2002-2008
- Renault Latitude
- Renault Koleos
Tech support from http://www.obd2france.com/

2016年9月22日星期四

How to start and login to Volvo VIDA 2014D with multiple languages

It’s aimed to make it easy to start and login to Volvo VIDA DICE 2014D with multiple languages.
VIDA 2014D PREREQUISITES:
- You need to have followed my "How to install Volvo VIDA 2014D on Windows 10" and have that up and running:
GUIDE:
To switch between two (or more) languages you need to change the language preferred by the user that logins to VIDA 2014D. These users are admin, 1, 2, 3 or 4 depending on your market. All these users get the language set by the patch that you installed earlier. To change the language you need to use OSQL.EXE to change the "AccessServer" database setting "Users""fkLanguage". I have created simple shortcuts to a batch file for you to run, to change between English (US), Swedish, Spanish, French and Polish in this example package.
A. Unpack the "set_fkLanguage_v2.7z" to C:\VIDA\ and it will unpack in "C:\VIDA\set_fkLanguage".
B. After you have unpacked the files, move the shortcut icons (VIDA en-US, VIDA sv-SE, VIDA es-ES, VIDA fr-FR, VIDA pt-PT) that corresponds to the languages that you have installed, to a preferred location of yours, e.g. the desktop.
C. To run VIDA DICE software in Swedish: double click the shortcut "VIDA sv-SE", to run VIDA in English (US): double click the shortcut "VIDA en-US" and so on.
D. Wait for the VIDA icon to turn green (it is in the task tray by the clock), then double click it to open VIDA in IE.
E. If you start VIDA 2014D by other means than the custom shortcuts, it will start with the last language used until you change it again with the custom shortcuts.
For those who want to use this package for another language not included:
- You need to copy one of the *.sql files, rename it to e.g. "de-DE.sql", edit the line to LanguageCode='de-DE' in that file, save it and then run it with this example from a command prompt (or create a new shortcut to it with the switch "de-DE" without the quotes after the target):
set_fkLanguage.cmd de-DE
Attachment:
set_fkLanguage_v2.7z:
http://multimirrorupload.com/8jso61dn2ae1/set_fkLanguage_v2.7z
NOTE: thanks for tanxeo sharing tips at http://forums.swedespeed.com/

2016年9月20日星期二

Where to get the CHEAPEST SPX AUTOBOSS OTC D730 scanner

How much is the AUTOBOSS OTC D730 from China?
At obd2france.com, the high-quality OTC D730 scan tool price is €869. It’s GENUINE.
Is it ok to get a cheap OTC D730? Any quality issues?
It is definitely quality-guaranteed with QC marks.
QC mark is inter-laboratory quality assessment scheme to promote quality immunohistochemistry. The programme measures staining quality as finial out come to assess techniques used and reagents employed. It tries to provide recommendation for improvement and give optimum protocol.
What can SPX AUTOBOSS OTC D730 contribute to auto repairing?
  1. Covers more than 50 vehicle makes
  2. Access to powertrain, chassis and body systems
  3. Quick Test function to test most vehicle systems
  4. Fault codes (DTC’s), Data Stream and Service Reset
  5. Actuations, Adaptations- and Control Module Coding
  6. Supports Multi-language for an international marketplace
  7. Frequent Internet based software updates
  8. CAN Bus with high/low speed
  9.  One OBD II/EOBD connector for all CAN Bus systems
  10. Demo Mode for many OEM’s
  11. Data graphing
  12. Self-check function
  13. Multi-language software including English, Italian, German, French, Spanish, Russian, Polish and Turkish, suitable for different language speakers
    14. With Built in Printer.
AUTOBOSS OTC D730 Scan tool support all auto systems?
Here are all tested systems that D730 supports:
Chassis :
SBC – Sensortronic Brake Control
ESP – Electronic Stability Program
AIRmatic – AIRmatic ABC
TPC – Tyre Pressure Monitor
ABS – SRS
Body:
Seats and Doors
Actual Values
Actuations
Initial Startup
Control Unit Adaptations
Correction Programming
Air Conditioning:
AAC – Automatic Air Conditioning
REAR AC – Rear Air Conditioning
STH – Stationary Heater
HSW – Heated Steering Wheel
Informatio n and Communication:
ICM – Instrument Cluster
SCM – Steering Column Module
PTS – Parktronic System
Audio, Video, Navigation
Telematics
Drive:
Transmission
ESM – Electronic Selector Module
DTR – Distronic
Motor Electronics
Idle Re-learn
Diesel Injector Coding
Diesel Pump Initialisation
DPF Regeneration
What about vehicles that D730 supports?
This scanner supports more than 50 vehicle makes all over the world.
Asian Vehicles :
Daewoo, Honda, Hyundai, Infiniti, Isuzu, Kia, Lexus, Mazda,Mitsubishi, Nissan, SangYong, Subaru, Suzuki and Toyota

American Vehicles:
Chrysler, Ford and General Motors
European Vehicles :
Audi, BMW, Citroen, Fiat, Ford, Jaguar, Lancia, Land Rover,Mini, Mercedes-Benz, Opel, Peugeot, Porsche, Renault, Seat,Skoda, Smart, Volkswagen and Volvo

Chinese Vehicles:
BYD, Chery, Foton, Geely,OERY, and Great Wall...
AUSTRALIAN Vehicles :
Ford and Holden
We can we do for you if you buy SPXAUTOBOSS OTC D730 Scanner?
-FREE to add new cars for you (if you need leave message on order )
1.Australia NEW added the cars list :AU-FORD,AU-HOLDEN
2.Eurasian version
New cars software list:

- fast shipping
- technique consultation
- quality guarantee for 1 year

Original:Where to get the CHEAPEST SPX AUTOBOSS OTC D730 scanner

2016年9月19日星期一

How to clean up a previous version of Volvo VIDA 2014D

  1. It’s about cleaning up a previous version of Volvo VIDA DICE 2014D francais or SQL (failed or not).
    STEP 1 THROUGH 8, CLEANING SECTION:
    1. Disconnect your Volvo DiCEdevice from your computer and do not connect it again until this guide says so.
    2. Make sure you have uninstalled everything related to VIDA:
    Uninstall in this order: (if you do not have some or any of these, uninstall the ones you have)
    - VIDA 2014D
    - Adobe Reader XI (11.0.06) (also remove any other version of Adobe Reader)
    - Dice Usb Driver x64
    - DiCE x64
    - IsoView
    - ITEDO IsoView ActiveX Control 4.0
    - Every instance that is named or begins with:
    "Microsoft SQL Server ...", e.g.
    "... Native Client",
    "... Setup (language)",
    "... Setup Support Files",
    "... Server Browser",
    "...VSS Writer",
    "... 64-bit)",
    "... Transact-SQL",
    "... Transact-SQL ScriptDom",
    "... System CLR Types",
    "... Management Objects", etc. REMOVE ALL VERSIONS OF Microsoft SQL Server.
    - Microsoft ODBC Driver ... for SQL Server
    - SQL Server Browser for SQL Server ...
    - Microsoft Visual Studio ...
    - Visual Studio ...
    - Microsoft .NET Framework 4 Multi-Targeting Pack
    - Windows Driver Package - SETEK AB (DiceUsb) DiCE Hardware (01/31/2011 6.1.7600.16385)
    Also remove any other SQL Server for that matter, and any versions of Java that you might have installed.
    - If you get an error that you cannot uninstall Microsoft SQL ... because "Microsoft SQL Server 2008 R2 RsFx Driver" is using it:
    Open a Command Prompt: Click Start and enter "CMD", then right click on "Command Prompt" and select "Run as Administrator". A new CMD-prompt will appear. Copy the following line depending on your architecture and then paste it by right clicking in the CMD-window and select "Paste", then hit enter:
    Code:
    MsiExec.exe /x {8FB7A1C3-87C4-4933-BE1D-6372CAF6A72E} /quiet
    1. To resolve problems with non-detected or problematic DiCE-devices/USB ports follow this optional procedure:
      3a. Disconnect your DiCE-device from your computer if you have not already done so.
      3b. Open Control Panel, open System, click Advanced System Settings, click Environment Variables on the Advanced tab, and define a new variable under System variables: Click "New...", Variable name: DevMgr_Show_NonPresent_Devices and set the Variable value to 1 and then click OK.
      3c. Open Device Manager and select View/Show hidden devices, remove the shadowed devices that are problematic, e.g.:
      - DiCE-206751@000000000000
      - Unknown USB Device (Device Descriptor Request Failed)4. To resolve issues with .NET Framework, follow this optional procedure:
      4a. Download the ".NET Framework Cleanup Tool" here:
      http://go.microsoft.com/fwlink/?LinkID=121918
      4b. Run the Cleanup Tool and select .NET Framework - All Versions (Windows ...)
      4c. Select "Cleanup Now" and wait for it to complete (reboot and then skip to step 5 if asked to reboot).4d. Reboot5. Delete folders: (if you do not have some or any of these, delete the ones you have)
      "C:\Program Files\Microsoft SQL Server"
      "C:\Program Files\DiCE"
      "C:\Program Files (x86)\Adobe\Reader 11.0"
      "C:\Program Files (x86)\Common Files\Adobe\Reader"
      "C:\Program Files (x86)\DiCE"
      "C:\Program Files (x86)\ITEDO Software"
      "C:\Program Files (x86)\Microsoft Visual Studio ... "
      "C:\Program Files (x86)\Microsoft SQL Server"
      "C:\Program Files (x86)\Volvo"
      "C:\Program Files (x86)\Volvo Cars"
      "C:\Users\[USERNAME]\AppData\Local\VIDA"
      "C:\Users\[USERNAME]\AppData\Roaming\ITEDO"
      "C:\VIDA"
      "C:\VIDASave"5b. Open a Command Prompt: Click Start and enter "CMD", then right click on "Command Prompt" and select "Run as Administrator". A new CMD-prompt will appear. Copy the following line and then paste it by right clicking in the CMD-window and select "Paste", then hit enter:
    Code:
    regsvr32 /s "C:\Windows\SysWOW64\cgmopenbho.dll"& del "C:\Windows\SysWOW64\cgmopenbho.dll"& del "C:\Windows\SysWOW64\cgmopenbho.cfg"
    1. Run regedit and remove the following keys: (if you do not have some or any of these, delete the ones you have)
      HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Ford Motor Company
      HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ITEDO Software
      HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\PassThruSu pport.04.04
      HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Volvo CarsRun CCleaner: (the free version)
      https://www.piriform.com/ccleaner/download
      - Start CCleaner and go to Options/Advanced and uncheck "Only delete files in Windows Temp folders older than 24 hours" and optionally uncheck "Show prompt to backup registry issues"
      - Under Options/Monitoring uncheck both "Enable system monitoring" and "Enable Active Monitoring"
      - Now run Cleaner (on the left) and after that go to Registry (also on the left) and run it multiple times until there longer are no issues detected.7b. Open Control Panel, open System, click Advanced System Settings, click Environment Variables on the Advanced tab, check if VIDA variables are in the list: if present, delete the following: VIDA_HOME, VIDA_LANGUAGE, VIDA LANGUAGES8. Reboot!Now follow the guide to install Volvo VIDA 2014D on Windows 10:

How to install Volvo VIDA 2014D on Windows 10 Pro x64

It’s a how-to guide to install Volvo VIDA 2014D on first and foremost Windows 10 Pro x64 but will work on most Windows 7, 8, 8.1 (32- and 64-bit) and up, especially on a system where VIDA has previously failed to install or a previous version of VIDA has been installed and then uninstalled. On a system such as that, the cleaning part step 1 through 8 is the most important part.
Usual errors on such systems are:
- An X is presented in Internet Explorer were the DICE Communication tool selector should be.
- You cannot enter anything in the Username login dialogue.
- "VIDA cannot start as port 80 is already in use".
- "VIDA NOT OK".
Check the troubleshooting section at the end of this guide for solutions.
REQUIREMENTS:- Microsoft Windows 10 Pro x86/x64 - I strongly recommend that you move to Windows to 64-bit. Especially if you are planning upgrading to SQL Server 2016.
- Volvo VIDA 2014D DVD or ISO-file
- VIDA Patch (2014A.exe works for VIDA 2014A through 2014D). File details:
2014A.exe 137 KB (140 785 bytes)
CRC32: E5F6F31C
MD5: 4E8084C08BDC59CB7D4DA16E708CDD8B
SHA-1: 4A1A38ECBF4608F7E36FDB38867F3A03D96D1B4C
GUIDE:If you have a clean install of Windows and have not previously installed any version of VIDA or SQL (failed or not): begin in this post with step 9.
On a system where VIDA has previously failed to install or a previous version of VIDA has been installed and then uninstalled, the cleaning part step 1 through 8 is the MOST IMPORTANT part, you will find that pre-install guide here:
http://blog.obd2france.com/2016/09/20/how-to-clean-up-a-previous-version-of-volvo-vida-2014d/
STEPS 9 THROUGH END, INSTALLING SECTION:9. Prepare your installation and download necessary files:
9a. Create a temporary directory in C:, and name it "VidaInstall". Continue with either x86 or x64 steps depending on your OS installation. x86 works on both 32-bit and 64-bit Windows, but I STRONGLY recommend you to follow the x64 steps on 64-bit Windows because this guide ASSUMES that you do.
nn_x86: This step is for Windows 32-bit. Skip this step if you are on Windows 64-bit.
nn_x64: This step is for Windows 64-bit. Skip this step if you are on Windows 32-bit.
9b_x86. Download:
- Java SE Development Kit 7u80 (x86) "jdk-7u80-windows-i586.exe" (138.35 MB) here:
http://www.oracle.com/technetwork/ja...k-7u80-oth-JPR
- Microsoft SQL Server 2008 R2 SP1 Express x86 English version is included on the VIDA 2014D DVD, no need to download it.
- Microsoft SQL Server 2008 R2 Service Pack 3 x86 English version "ENU\SQLServer2008R2SP3-KB2979597-x86-ENU.exe" (247.2 MB) here:
https://www.microsoft.com/en-us/down....aspx?id=44271
9b_x64. Download:
- Java SE Development Kit 7u80 (x64) "jdk-7u80-windows-x64.exe" (140.09 MB) here:
http://www.oracle.com/technetwork/ja...k-7u80-oth-JPR
- Microsoft SQL Server 2008 R2 SP1 Express x64 English version "ENU\SQLEXPR_x64_ENU.exe" (117.5 MB) here:
http://www.microsoft.com/en-us/downl....aspx?id=26729
- Microsoft SQL Server 2008 R2 Service Pack 3 x64 English version "ENU\SQLServer2008R2SP3-KB2979597-x64-ENU.exe" (358.4 MB) here:
http://www.microsoft.com/en-us/downl....aspx?id=44271
9c_x86. Prepare:
- After the Java SE Development Kit download is complete, open the VIDAInstall directory and create a new folder in there, name it "JDK7u80". Move the "jdk-7u80-windows-i586.exe" to the C:\VIDAInstall\JDK7u80 folder.
- After the SQL Server SP3 download is complete, open the VIDAInstall directory and create a new folder in there, name it "SQL2008R2SP3". Move the "SQLServer2008R2SP3-KB2979597-x86-ENU.exe" to the C:\VIDAInstall\SQL2008R2SP3 folder.
9c_x64. Prepare:
- After the Java SE Development Kit download is complete, open the VIDAInstall directory and create a new folder in there, name it "JDK7u80". Move the "jdk-7u80-windows-x64.exe" to the C:\VIDAInstall\JDK7u80 folder.
- After the SQL Server SP1 download is complete, open the VIDAInstall directory and create a new folder in there, name it "SQL2008R2SP1". Move the "SQLEXPR_x64_ENU.exe" to the C:\VIDAInstall\SQL2008R2SP1 folder.
- After the SQL Server SP3 download is complete, open the VIDAInstall directory and create a new folder in there, name it "SQL2008R2SP3". Move the "SQLServer2008R2SP3-KB2979597-x64-ENU.exe" to the C:\VIDAInstall\SQL2008R2SP3 folder.
9d. Install Microsoft SQL Server 2008 R2 SP1 Express:
- Open a Command Prompt: Click Start and enter "CMD", then right click on "Command Prompt" and select "Run as Administrator". A new CMD-prompt will appear. Copy the following line depending on your architecture and then paste it by right clicking in the CMD-window and select "Paste", then hit enter:
- For Windows x86: (substitute D: for your actual VIDA DVD location))
Code:
"D:\3PP\Products\SqlExpress\SQLEXPR_x86_ENU.exe" /ACTION=Install /IACCEPTSQLSERVERLICENSETERMS /ROLE=AllFeatures_WithDefaults /INSTANCENAME=VIDA /SAPWD=GunnarS3g3 /SECURITYMODE=SQL /SQLSVCACCOUNT="NT AUTHORITY\SYSTEM" /BROWSERSVCSTARTUPTYPE=Automatic /TCPENABLED=1 /HIDECONSOLE /ENU /QS
- For Windows x64:
Code:
"C:\VIDAInstall\SQL2008R2SP1\SQLEXPR_x64_ENU.exe" /ACTION=Install /IACCEPTSQLSERVERLICENSETERMS /ROLE=AllFeatures_WithDefaults /INSTANCENAME=VIDA /SAPWD=GunnarS3g3 /SECURITYMODE=SQL /SQLSVCACCOUNT="NT AUTHORITY\SYSTEM" /BROWSERSVCSTARTUPTYPE=Automatic /TCPENABLED=1 /HIDECONSOLE /ENU /QS
- The installation of SQL Server will run by itself without any user intervention. Wait until it is complete and then close the Command Prompt.
10. Optional step: Make sure Internet Explorer 11 is installed via Control Panel: View by: Small icons, "Programs and Features", select "Turn Windows features on or off" and make sure Internet Explorer 11 is checked (which is the default in Windows 10).
11. Optional step: If you do not want the automatic download of .NET Framework 3.5 during the installation:
- Go to Control Panel, open "Programs and Features", click on "Turn Windows features on or off".
- Check the box for ".NET Framework 3.5 (includes .NET 2.0 and 3.0)" (if it is not already checked) and then click OK.
12-15. Steps removed.
16. Install VIDA from the VIDA 2014D DVD:
16a. Step removed.
16b. Locate VIDA Setup (setup.exe) in "D:\Install\DVD\Vida_dvdheader\Main" (NOT the setup.exe in the Vida folder) (substitute D: for your actual VIDA DVD location), right click the file and select Properties, go to the Compatibility tab, check "Run this program in compatibility mode for:" and select "Windows 7" from the drop down list, then click OK.
16c. Now run the "setup.exe", still in the Main folder.
- Select VIDA All-in-one and then the language(s) to install. (WARNING! You cannot install another language after you have upgraded SQL!) (For a multi-language setup, first follow this guide and then my "VIDA Multi-language Guide").
- Leave the default Destination folder as is (C:\VIDA\) and click Next.
- Accept the License Agreement.
- If the installation asks to download .NET Framework 3.5, select to "Download and install this feature". After the downloading and installing is done click Close.
- When the Vida Configurator shows up, leave the default selection on the Location tab as is, which is "Internet", (do not change anything on the other tabs) click Save and then Close, Close.
- WARNING! If you get an "Unhandled Exception" during Multi-language setup, see the Troubleshooting section at the end of this guide BEFORE you continue!
- When Setup asks for a reboot, select "No, I will restart my computer later" and then click Finish.
- If Windows Firewall Security Alert shows up for "Java(TM) Platform SE binary", tick both "Private networks" and "Public networks" and click "Allow access".
16d. To fix an incompatibility issue with this old Java version that comes pre-installed with VIDA and Windows Update "KB3163018" (and also pre-installed with Windows 10 v.1607) you need to update Java:
- Uninstall all Java versions (if not already done so).
16e. Make sure that VidaMonitor and Java are closed (they will be started only if you have installed multi-language, but check to make sure anyway): Start Windows Task Manager and click "More details". Locate and right click "VidaMonitor.exe" on the "Details" tab and select "End task", confirm by clicking "End process". Do the same with java.exe and javaw.exe. Close Windows Task Manager.
- Close Internet Explorer.
nn_x86: This step is for Windows 32-bit. Skip this step if you are on Windows 64-bit.
nn_x64: This step is for Windows 64-bit. Skip this step if you are on Windows 32-bit.
16f_x86. On Windows x86 do the following:
- Install: C:\VIDAInstall\JDK7u80\jdk-7u80-windows-i586.exe
- Rename "jdk" folder in "C:\VIDA\" to "jdk.old" (or delete it).
- Copy folder "jdk1.7.0_80" from "C:\Program Files\Java" to "C:\VIDA\".
- Rename folder "jdk1.7.0_80" in "C:\VIDA\" to "jdk".
- Uninstall "Java SE Development Kit 7 Update 80" and "Java 7 Update 80" from Control Panel Programs and Features, you do not need it anymore as all the files VIDA uses we have already copied.
16f_x64. On Windows x64 do the following:
- Install: C:\VIDAInstall\JDK7u80\jdk-7u80-windows-x64.exe
- Rename "jdk" folder in "C:\VIDA\" to "jdk.old" (or delete it).
- Copy folder "jdk1.7.0_80" from "C:\Program Files\Java" to "C:\VIDA\".
- Rename folder "jdk1.7.0_80" in "C:\VIDA\" to "jdk".
- Uninstall "Java SE Development Kit 7 Update 80 (64-bit)" and "Java 7 Update 80 (64-bit)" from Control Panel Programs and Features, you do not need it anymore as all the files VIDA uses we have already copied.
17. Now it is time to install the VIDA Patch (2014A.exe -- check the size or better yet the MD5 or SHA-1 under Requirements in this guide above, to match. You might otherwise have downloaded a virus), the same Patch works for VIDA 2014A through 2014D:
17a. Make sure that VidaMonitor is closed: Start Windows Task Manager and click "More details". Locate and right click "VidaMonitor.exe" on the "Details" tab and select "End task", confirm by clicking "End process". Close Windows Task Manager.
nn_x86: This step is for Windows 32-bit. Skip this step if you are on Windows 64-bit.
nn_x64: This step is for Windows 64-bit. Skip this step if you are on Windows 32-bit.
17b_x86: Now it's time to run the VIDA Patch, the same Patch works for VIDA 2014A through 2014D. "2014A.exe". Run it as Administrator and leave the default Destination folder as is (c:\) and select Install. Ignore the taskkill error. Now skip to step 18.
17b_x64: Do NOT try to install it by running the exe, instead use Z-zip to unpack the compressed files directly to C: (running it will not always work with this setup and will sometimes not patch the installation correctly).
17c_x64. Right click and select "Extract files..." Enter C: in the "Extract to" field and untick the "2014A\" path.
17d_x64. The package will extract to the VIDA-folder, overwrite all files when asked.
17e_x64. Locate the file filldb.cmd in the "C:\VIDA\patch" folder and then right click on it, select "Run as administrator". You will briefly see a CMD-prompt that opens and closes quickly, this is by design and no other confirmation will appear.
18. Now apply the Microsoft SQL Server 2008 R2 SP3 Express Service Pack (KB2979597 - a prerequisite for the SQL 2016 upgrade):
18a. Open a Command Prompt: Click Start and enter "CMD", then right click on "Command Prompt" and select "Run as Administrator". A new CMD-prompt will appear. Copy the following line depending on your architecture and then paste it by right clicking in the CMD-window and select "Paste", then hit enter:
- For Windows x86: (substitute D: for your actual VIDA DVD location))
Code:
"C:\VIDAInstall\SQL2008R2SP3\SQLServer2008R2SP3-KB2979597-x86-ENU.exe" /IACCEPTSQLSERVERLICENSETERMS /ALLINSTANCES /HIDECONSOLE /ENU /QS
- For Windows x64:
Code:
"C:\VIDAInstall\SQL2008R2SP3\SQLServer2008R2SP3-KB2979597-x64-ENU.exe" /IACCEPTSQLSERVERLICENSETERMS /ALLINSTANCES /HIDECONSOLE /ENU /QS
- The upgrade of SQL Server will run by itself without any user intervention. Wait until it is complete and then close the Command Prompt.
18c. Reboot.
19. If Windows Firewall Security Alert shows up for "Java(TM) Platform SE binary", tick both "Private networks" and "Public networks" and click "Allow access".
20. Now you should be ready to try VIDA out, but wait for the VIDA Monitor to change to a green play icon (VIDA Monitor is by the task tray):
20a. Connect your DiCE-device to your computer.
20b. Start VIDA All-In-One
20c. If Internet Explorer ask to use Recommended security and compatibility settings chose "Don't use recommended settings".
20d. If Internet Explorer asks permission to enable Several add-ons, click Choose add-ons and Enable both 'Adobe PDF Link Helper' and 'WebCGMHlprObj Class'. If Internet Explorer only asks permission to enable 'WebCGMHlprObj Class' click "Enable".
20e. Login with admin, 1, 2, 3 or 4, depending on your location/market.


Volvo VIDA DICE 2014D TROUBLESHOOTING:PROBLEM: An X is presented in Internet Explorer were the DICE Communication tool selector should be (this happens after a Windows upgrade).
SOLUTION: Locate on your VIDA DVD the directory D:\Install\Utils (substitute D: for your actual VIDA DVD location) and the file "EnableIEHostingx64.reg" and merge it with the registry by double clicking on it and then select "Yes" and "OK". For x86 systems do the same with "EnableIEHostingx86.reg"
PROBLEM: You cannot enter anything in the Username login dialogue.
SOLUTION: You have not applied the patch correctly, do step 17 again and then reboot.
SOLUTION 2: Install the patch the "old way":
1. Make sure that VidaMonitor and Java are closed: Start Windows Task Manager and click "More details". Locate and right click "VidaMonitor.exe" on the "Details" tab and select "End task", confirm by clicking "End process". Do the same with java.exe and javaw.exe. Close Windows Task Manager. If Windows Firewall Security Alert shows up for "Java(TM) Platform SE binary", tick both "Private networks" and "Public networks" and click "Allow access".
PROBLEM: "VIDA cannot start as port 80 is already in use".
SOLUTION: Uninstall or disable any services you may have installed that uses port 80, usually Web-servers. IIS may be the culprit: Control Panel/Programs and Features/Turn Windows features on or off - Internet Information Services.
PROBLEM:
Could not load file or assembly 'BizServices.VehicleImageRepository, Version=2.0.5394.27556, Culture=neutral, PublicKeyToken=null' or one of its dependencies. The system cannot find the file specified.
SOLUTION: NONE YET  I ended up cleaning ALOT of stuff in Windows followed by a Windows "repair upgrade". After that, it worked. This is the file it says it cannot find:
"C:\VIDA\jboss\standalone\deployments\VidaEar.ear\V idaWeb.war\Diagnostics\BizServices.VehicleImageRep ository.DLL"
Same error shows up in a working VIDA environment if you temporary rename or remove BizServices.VehicleImageRepository.DLL.
PROBLEM:
During Multi-language installation, in some cases, this error will appear while trying to install second language:
Unhandled Exception Error Number: 0x80004005 Description: [Microsoft][ODBC SQL Server Driver]Login timeout expired Setup will now terminate.
SOLUTION:
- Select OK and then prepare to be greeted by the infamous "VIDA NOT OK" message.
- Select "Yes, I want to restart my computer now."
- After the reboot, make sure that VidaMonitor is closed: Start Windows Task Manager and click "More details". Locate and right click "VidaMonitor.exe" on the "Details" tab and select "End task", confirm by clicking "End process".
- Now re-run setup, again select VIDA All-in-one, and then select only the additional language that you tried to install when it failed (it is probably already selected -- I here presume that you tried to install an additional language to en-US).
- When Setup asks for a reboot, select "No, I will restart my computer later." and then click Finish.
- Now continue to follow my guide from step 16d.
PROBLEM: Other problem.
SOLUTION: Other problems can often be solved by starting over and go through the steps 1 through 8 and not skipping them in my guide. Print out the guide on paper and do a check mark for the things you have already done to make sure you are not missing any crucial point.